If replacing the main battery, reset the main battery capacity information and the control
information.
|
|
1.Connect the M.U.T.-III to the diagnosis connector with the electric motor switch in the
"LOCK" (OFF)position. 2.Turn the electric motor switch to the ON position. 3.From the System select Screen of the M.U.T.-III, select the "BMU". 4.Select the "Special Function" from the BMU screen. 5.Select the "Reset" from the Special Function screen 6.Select the "Battery capacity estimated info" from the Reset screen, and reset. 7.After the estimated information of the main battery capacity is reset, select "Control
information" from the Reset Screen to reset. 8.Put the power switch in the LOCK (OFF) position. 9.After the reset of the BMU control information, check the battery current capacity
according to the following procedures: (1)
After 10 seconds elapsed from the previous process, turn on the power switch. (2)
Select the "STV (Scan Tool Viewer)" from the M.U.T.-III start screen. (3)
Select the "System Select" from the fault STV top menu screen. (4)
Select the "BMU" from the system select screen. (5)
Select the "Service Data" from the BMU screen. (6)
Check the BMU service data, item No. 23: Battery current capacity. (7)
If the value, item No. 23: Battery current capacity, satisfies 45.0 - 48.0