CHECK AND REPLACEMENT OF THE HIGH-VOLTAGE FUSE INSIDE THE INVERTER


danger When servicing the high-voltage system parts, be sure to wear the specified protection equipment and disconnect the service plug to interrupt the high-voltage supply (Refer to ).
1.Remove the luggage room floor carpet.

2.Remove the electric motor unit inspection lid.
3.Remove the inverter service lid (refer to .)

4.Remove each installation screw and remove the high-voltage fuse.
5.check the resistance between the high-voltage fuses, and if there is no continuity (open circuit), replace the high-voltage fuses.
6.
caution When tightening the installation screws, secure the high-voltage fuse terminal portion, because there is a risk of damage to the high-voltage fuse when an excessive force applies to the high-voltage fuse main body.
Tighten each installation screw to the specified torque.
Tightening torque: 1.8 ± 0.1 N·m
7.Install the inverter service lid (refer to .)
8.Install the electric motor unit inspection lid.
9.Install the luggage room floor carpet.