Code No. P1A8E: CMU01 balancer abnormal, P1A8F: CMU02 balancer abnormal, P1A90: CMU03 balancer abnormal, P1A91: CMU04 balancer abnormal, P1A92: CMU05 balancer abnormal, P1A93: CMU06 balancer abnormal, P1A94: CMU07 balancer abnormal, P1A95: CMU08 balancer abnormal, P1A96: CMU09 balancer abnormal, P1A97: CMU10 balancer abnormal, P1A98: CMU11 balancer abnormal, P1A99: CMU12 balancer abnormal




TROUBLE JUDGMENT


Check Conditions
  • 3 seconds elapse after the electric motor switch is turned ON, or 3 seconds elapse after the main battery starts to be charged.
  • Balancer allowed to be driven is OFF.
  • None of the following diagnosis codes occur at the same time.

    1. P1AA8: Local CAN (for main battery) signal time-out
    2. U1082: Local CAN (for main battery) bus off
Judgement Criterion
  • The signal is received from the appropriate module CMU, which shows that one of the balancer driving conditions is turned ON.

FAIL-SAFE AND BACKUP FUNCTION



  • Not available

PROBABLE CAUSES



  • The module (CMU) in the main battery is failed.
  • The BMU is failed.

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III data list



  • Check the data list reference table corresponding to the diagnosis code (Refer to ).
OK: OFF (electric motor switch: ON)

Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
Go to Step 2 .

STEP 2. After replacing the main battery, reconfirm the diagnosis code.



  • After replacing the main battery, reconfirm whether the diagnosis codes are set.

Q. Is the diagnosis code set?

Replace the BMU.
Check end.