INSPECTION



POWER WINDOW MAIN SWITCH CONTINUITY CHECK





<DRIVER’S SWITCH>
Switch position
Tester connection
Specified condition
UP
4 - 5,
3 - 8
Continuity exists (2 Ω or less)
OFF
4 - 8,
3 - 8
DOWN
3 - 5,
4 - 8

<FRONT PASSENGER’S SWITCH>
Switch position
Tester connection
Specified condition
UP
2 - 10,
2 - 8*
Continuity exists (2 Ω or less)
OFF
2 - 8*,
1 - 8*
DOWN
1 - 10,
1 - 8*
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S LEFT SWITCH>
Switch position
Tester connection
Specified condition
UP
10 - 16,
8* - 16
Continuity exists (2 Ω or less)
OFF
8* - 15,
8* - 16
DOWN
10 - 15,
8* - 15
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S RIGHT SWITCH>
Switch position
Tester connection
Specified condition
UP
10 - 12,
8* - 12
Continuity exists (2 Ω or less)
OFF
8* - 11,
8* - 12
DOWN
10 - 11,
8* - 11
note *: Set the window lock switch to UNLOCK position.

POWER WINDOW SUB SWITCH CONTINUITY CHECK




Switch position
Tester connection
Specified condition
UP
4 - 5, 6 - 7
Continuity exists (2 Ω or less)
OFF
4 - 5, 7 - 8
DOWN
4 - 6, 7 - 8

POWER WINDOW MOTOR CONTINUITY CHECK



1.Connect a battery to the motor terminals and check that the motor runs smoothly.
2.Check that the motor runs in the opposite direction when the battery is connected with the polarity reversed.
3.If a defect is found, replace the power window motor assembly.



<FRONT DOOR (LH)>
Tester connection
Slider position
1(-) - 3(+)
UP
1(+) - 3(-)
DOWN



<FRONT DOOR (RH)>
Tester connection
Slider position
1(-) - 2(+)
UP
1(+) - 2(-)
DOWN



<REAR DOOR>
Tester connection
Slider position
1(-) - 4(+)
UP
1(+) - 4(-)
DOWN





Yandex.Metrika