FUEL TEMPERATURE SENSOR CHECK



1.Disconnect the fuel temperature sensor connector.
2.Measure the resistance between terminal No. 1 and No. 2
Standard value: Approximately 2.0 - 3.0 kΩ (at 20 °C)
3.If not within the standard value, replace the supply pump assembly. After replacing the supply pump, learn the supply pump (Refer to GROUP 00 - Precautions before Service - What the Common Rail Learns )