A/T FLUID CHANGE


If there is an ATF changer, use it. If there is no ATF changer, replace the fluid as described below.

note If you use an ATF changer, disconnect the oil return hose from the oil return tube. Then connect the ATF changer between them.



1.
caution When draining the fluid from the drain plug hole, use a plate to prevent the fluid from dripping on the centre member assembly.
Remove the filler plug and the drain plug, and drain the fluid from the drain plug hole.
Discharge volume: Approx. 3.0 L
2.Install the drain plug with a new gasket in between, and tighten it to the specified torque.
Tightening torque: 20 ± 2 N·m
3.Remove the overflow plug.
4.Pour in the fluid through the filler plug hole until the fluid is drained from the overflow plug hole. Wait until the fluid becomes oil drops, and then tighten the overflow plug with a new gasket and the filler plug with a new O-ring to the specified torque.
Tightening torque:

    20 ± 2 N·m (overflow plug)
    39 ± 15 N·m (filler plug)
5.Check the fluid level (refer to ).
6.During the fluid level check, check the drained fluid for contamination. If the fluid is contaminated, perform steps 1 to 5 again.