INSPECTION



FRONT DOOR LOCK ACTUATOR CHECK




ACTUATOR OPERATION CHECK
Lever position
Battery connection
Lever operation
At the "LOCK" position

  • Connect terminal No.4 and the negative battery terminal.
  • Connect terminal No.6 and the positive battery terminal.

The lever moves from the "LOCK" position to the "UNLOCK" position.
At the "UNLOCK" position

  • Connect terminal No.6 and the negative battery terminal.
  • Connect terminal No.4 and the positive battery terminal.

The lever moves from the "UNLOCK" position to the "LOCK" position.

ACTUATOR SWITCH CHECK <DRIVER’S SIDE (LHD)>
Lever position
Tester connection
Specified condition
At the "UNLOCK" position
1 - 3
Continuity exists (2 Ω or less)
At the "LOCK" position
1 - 2
Continuity exists (2 Ω or less)

ACTUATOR SWITCH CHECK <DRIVER’S SIDE (RHD)>
Lever position
Tester connection
Specified condition
At the "UNLOCK" position
2 - 3
Continuity exists (2 Ω or less)
At the "LOCK" position
1 - 3
Continuity exists (2 Ω or less)

REAR DOOR LOCK ACTUATOR CHECK




ACTUATOR OPERATION CHECK
Lever position
Battery connection
Lever operation
At the "LOCK" position

  • Connect terminal No.4 and the negative battery terminal.
  • Connect terminal No.6 and the positive battery terminal.

The lever moves from the "LOCK" position to the "UNLOCK" position.
At the "UNLOCK" position

  • Connect terminal No.6 and the negative battery terminal.
  • Connect terminal No.4 and the positive battery terminal.

The lever moves from the "UNLOCK" position to the "LOCK" position.