1.Remove the power window fuse, and connect a multimeter as shown in the illustration. 2.Raise the power window to measure the current during operation. Standard value range: 7 A or less (Power supply voltage 14.5±0.5 V, at
25°C)
| note |
If the power supply voltage does not meet the standard value, check and repair the auxiliary
battery. Then carry out this check again.
|
3.If the value is outside the standard value, adjust the door window glass (refer to ).
|