REMOVAL AND INSTALLATION



caution
  • Disconnect the negative auxiliary battery terminal and wait for 60 seconds or more before starting work. Insulate the disconnected (-)terminal by wrapping the tape (Refer to the item 5 of Service Precautions ).
  • Never attempt to disassemble or repair the rear detect sensor. If faulty, replace it with new one.
  • Do not drop the rear detection sensor or apply any impact or vibration to it. If there is a dent, crack, or deformation, replace with a new sensor.
  • After the judgment of high voltage shutdown, replace the rear detection sensor with a new one.
Pre-removal operation
  • Electric motor switch to the LOCK (OFF) position.
  • Disconnect the negative auxiliary battery terminal.





Removal steps


·
Rear floor cover panel (RH) (Refer to GROUP 42 -Loose panel)
<<A>>

1.
Rear detect sensor connector


2.
Rear detect sensor



Installation steps

>>A<<
·
Pre-installation inspection

>>B<<
2.
Rear detect sensor


1.
Rear detect sensor connector


·
Rear floor cover panel (RH) (Refer to GROUP 42 -Loose panel)

>>C<<
·
Post-installation inspection

REMOVAL SERVICE POINTS



<<A>> REAR DETECT SENSOR REMOVAL



Slide the connector lock of rear detection sensor harness connector to the direction of the arrow, then unlock and disconnect the connector.

INSTALLATION SERVICE POINTS



>>A<< PRE-INSTALLATION INSPECTION


Before the installation, check the rear detect sensor (Refer to ).
note Even when installing a new rear detect sensor, perform an inspection before the installation.

>>B<< REAR DETECT SENSOR INSTALLATION


caution If the rear detection sensor is not securely and correctly installed, the correct control of high-voltage shutdown judgment is prevented.

>>C<< POST-INSTALLATION INSPECTION


1.Electric motor switch to the "ON" position.

2.Check that the SRS warning lamp is illuminated for 6 to 8 seconds, and extinguished afterward.
3.If the lamp does not extinguish, perform the troubleshooting (Refer to ).





Yandex.Metrika