Check room lamp fuse No. 13 in the junction block is blown or pulled off.
|
|
|
Q.
Is the check result normal?
|
|
|
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How
to use Troubleshooting/inspection Service Points - Inspection service points
for a blown fuse ).
|
|
|
|
|
|
Check that the low-beam and high-beam headlamps work normally.
|
|
|
Q.
Is the check result normal?
|
|
|
Follow Inspection Procedure 1: None of the low-beam headlamps illuminate (Refer
to ) and Inspection Procedure 2: None of the high-beam headlamps illuminate
(Refer to ). Then go to Step 4.
|
|
|
|
|
|
Check if the ETACS-ECU sets a diagnosis code.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Diagnose the ETACS-ECU.(Refer to ) After the repair,
go to Step 4.
|
|
|
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the defective connector.
|
|
|
|
|
|
(1)Disconnect the connector, and measure at the wiring harness-side connector.
|
|
|
(2)Voltage between B-201 column switch connector connector terminal No.1 and the body
earth OK: System voltage
|
|
|
Q.
Is the check result normal?
|
|
|
- Check the power supply line for open circuit and short circuit.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the wiring harness.
|
|
|
|
|
|
Check whether the headlamps illuminate briefly when the electric motor switch is turned
to the ON position with the lighting switch in the OFF or TAIL position.
|
|
|
Q.
Is the check result normal?
|
|
|
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How
to use Troubleshooting/inspection Service Points - How to Cope with Intermittent
Malfunction ).
|
|
|
|
|
|
Replace the column switch (wiper and washer switch).
|
|
|
|