METER BRIGHTNESS SETTING



The brightness of the combination meter can be set in 4 steps (STEP 1 to STEP 4) as the following procedure.

HOW TO SET


1.

The meter brightness is displayed on the odometer/tripmeter display by operating the adjusting button of the meter brightness. When the meter mode is set, the meter brightness indicator illuminates, and the present brightness level is displayed on the odometer/tripmeter display.
2.

If the meter brightness adjusting button is pressed and held for 1.2±0.2 seconds or longer with a meter mode, the odometer/tripmeter display switches in numerical order as shown in the figure. The meter brightness is set to the very brightness when the adjusting button was released. For the each brightness level, refer to the table below.
note The brightness can be set between daytime and nighttime respectively, and it is stored in the RAM. The default of the brightness is set to STEP 4 in the daytime, and to STEP 3 in the nighttime.
3.If the adjusting button of the meter brightness is not operated for 10±1 seconds or longer with a meter mode, and that the electric motor switch is set from ON to OFF (or from OFF to ON), the rheostat mode will be terminated.

BRIGHTNESS LEVEL TABLE


Brightness level
Panel brightness
Pointer brightness
LCD display brightness
Brightness of position lamp indicator *
Day
Night
Day
Night
Day
Night
Day
Night
STEP 4
100%
100%
100%
100%
100%
100%
100%
100%
STEP 3
50%
50%
50%
40%
50%
20%
100%
50%
STEP 2
25%
25%
25%
20%
25%
13.5%
100%
50%
STEP 1
12.5%
12.5%
12.5%
10%
12.5%
7.5%
100%
50%
note *: The brightness of the position lamp indicator shows the brightness when the indicator is turned on.