Q.
Is the check result normal?
|
|
|
Repair the defective connector.
|
|
|
|
|
|
Check the bulb(s) of the licence plate lamp that does not illuminate.
|
|
|
Q.
Is the check result normal?
|
|
|
Replace the bulb(s) of the licence plate lamp that does not illuminate.
|
|
|
|
|
|
(1)Disconnect the connector and measure at the wiring harness side.
|
|
|
(2)Measure resistance between F-03 (RH) or F-07 (LH) licence plate lamp connector
terminal No. 1, which does not illuminate, and body earth OK: Continuity exists (2 Ω or less)
|
|
|
Q.
Is the check result normal?
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the defective connector.
|
|
|
|
|
|
- Check the earth wires for open circuit.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the wiring harness.
|
|
|
|
|
|
- Check the power supply line for open circuit.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the wiring harness.
|
|
|
|
|
|
Check that the licence plate lamp illuminates normally.
|
|
|
Q.
Is the check result normal?
|
|
|
YES) : The trouble can be an intermittent malfunction (Refer to GROUP 00 - How
to use Troubleshooting/inspection Service Points - How to Cope with Intermittent
Malfunction ).
|
|
|
|
|
|
Replace the socket of the defective licence plate lamp.
|
|
|
|