The EV-ECU monitors the backup lamp relay coil drive circuit.
DIAGNOSIS CODE SET CONDITIONS
When the backup lamp relay coil drive circuit monitor
is set to ON while the backup lamp relay stop command is underway, the diagnosis code No. P1A0E
will be set.
When the backup lamp relay coil drive circuit monitor is set to OFF while the backup
lamp relay drive command is underway, the diagnosis code No. P1A0F will be set.
PROBABLE CAUSES
Malfunction of the backup lamp relay
Damaged wiring harness or connector(s)
Malfunction of the EV-ECU
DIAGNOSIS PROCEDURE
STEP 1. M.U.T.-III actuator test
Conduct the actuator test, and check the backup lamp relay. (Refer to .)
Actuator test
Item No. 8 : Back-up lamp relay drive
OK: The backup lamp relay operates normally.
Q.
Is the check result normal?
Go to Step 7.
Go to Step 2.
STEP 2. Voltage measurement at C-108 EV-ECU connector
(1)C-108 Disconnect the EV-ECU connector, and measure the resistance at the wiring
harness side.
(2)Turn the electric motor switch to the "ON" position.
(3)Measure the voltage between the C-108 EV-ECU connector terminal No. 57 and the
body earth. OK: Battery voltage