MSB is released for this page as follows:
Release DateSubjectMSB No.
2014-01-13CAUTION STATEMENTS REGARDING MAINTENANCE OF HIGH VOLTAGE PARTSMSB-13EXML54-006A
2014-01-17CAUTION STATEMENTS REGARDING MAINTENANCE OF HIGH VOLTAGE PARTSMSB-13EXML54-006B

Code No. P1B02: Quick charger current stop time-out
Code No. P1B03: Quick charger end processing time-out



QUICK CHARGING CONTROL SYSTEM CIRCUIT







OPERATION




DIAGNOSIS CODE SET CONDITIONS




PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Connector check: G-10 quick charging connection, C-106, C-111 EV-ECU connector


Q. Is the check result normal?

Go to Step 2.
Repair the damaged connector.

STEP 2. Check the wiring harness between G-10 quick charging connection terminal No. 4, 6, 10 and C-111 EV-ECU connector terminal No. 111, 124 and C-106 EV-ECU connector terminal No. 4.


Check the signal lines for short to earth or open circuit.

Q. Is the check result normal?

Check the quick charger. Then go to Step 3.
Repair the wiring harness.

STEP 3. Diagnosis code recheck


Check again if the diagnosis code is set to the EV-ECU.
(1)Erase the stored diagnosis code.
(2)Set the electric motor switch from the "LOCK" (OFF) position to the "ON" position.
(3)Check if the diagnosis code is set.

Q. Is the diagnosis code set?

Return to Step 1.
The diagnosis is complete.