MSB is released for this page as follows:
Release DateSubjectMSB No.
2014-01-13CAUTION STATEMENTS REGARDING MAINTENANCE OF HIGH VOLTAGE PARTSMSB-13EXML54-006A
2014-01-17CAUTION STATEMENTS REGARDING MAINTENANCE OF HIGH VOLTAGE PARTSMSB-13EXML54-006B

Code No. U116A: Local CAN (for quick charger) bus-off
Code No. U116B: Quick charger local CAN (for quick charger) time-out



QUICK CHARGING CONTROL SYSTEM CIRCUIT







OPERATION




DIAGNOSIS CODE SET CONDITIONS




PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Measure the local CAN (for quick charger) terminator resistor.


(1)C-111 Disconnect the EV-ECU connector, and measure the resistance at the wiring harness side.
(2)Connect the quick charger.
(3)Measure the resistance between terminal No. 101 and No. 102.
OK: 120±20 Ω

Q. Is the check result normal?

Go to Step 4.
Go to Step 2.

STEP 2. Check the local CAN (for quick charger) bus connector. G-10 quick charging connection, C-111 EV-ECU connector


Q. Is the check result normal?

Go to Step 3.
Repair the damaged connector.

STEP 3. Check the local CAN (for quick charger) bus line between the G-10 quick charging connection terminal No. 8, 9 and C-111 EV-ECU connector terminal No. 101, 102.


Check the signal lines for short to earth or open circuit.

Q. Is the check result normal?

Check the quick charger. Then go to Step 4.
Repair the local CAN (for quick charger) bus line.

STEP 4. Diagnosis code recheck


Check again if the diagnosis code is set to the EV-ECU.
(1)Erase the stored diagnosis code.
(2)Set the electric motor switch from the "LOCK" (OFF) position to the "ON" position.
(3)Check if the diagnosis code is set.

Q. Is the diagnosis code set?

Replace the EV-ECU. (Refer to .) Then go to Step 5.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction .)

STEP 5. Diagnosis code recheck


Check again if the diagnosis code is set to the EV-ECU.
(1)Erase the stored diagnosis code.
(2)Set the electric motor switch from the "LOCK" (OFF) position to the "ON" position.
(3)Check if the diagnosis code is set.

Q. Is the diagnosis code set?

Return to Step 1.
The diagnosis is complete.





Yandex.Metrika
MMC-Manuals.ru