CHECK AT ECU TERMINALS




Terminal No.
Check item
Inspection conditions
Normal conditions
1 - 3
-
-
-
4
Inverter shutdown signal

  • Electric motor switch: ON position
  • Selector lever: P position

1 V or less

  • Electric motor switch: ON position
  • Selector lever: D position

Battery voltage
5
ECU control power supply input

  • Electric motor switch: ON position
  • Selector lever: P position

Battery voltage
Electric motor switch: LOCK (OFF) position
1 V or less
6 - 8
-
-
-
9
K-LINE communication

  • Electric motor switch: ON position
  • Selector lever: P position

0 to 12 V (pulse signal)
Electric motor switch: LOCK (OFF) position
1 V or less
10
ECU power supply earth
Always
1 V or less


Terminal No.
Check item
Inspection conditions
Normal conditions
1 - 3
-
-
-
7 - 9
-
-
-
4
S2
Do not check because there is a risk of damage to the ECU.
-
5
S1
6
R1
10
-
-
-
11
S4
Do not check because there is a risk of damage to the ECU.
-
12
S3
13
R2

CHECK AT THE MOTOR (ELECTRIC MOTOR UNIT) TERMINAL




Terminal No.
Check item
Inspection conditions
Normal conditions
1
-
-
-
7
-
-
-
2
U-phase coil temperature
Measure the resistance value between the terminal No. 2 - No. 8 with the connector disconnected.
12.3 to 12.8 kΩ: 20°C
5.6 to 6.1 kΩ: 40°C
2.8 to 3.2 kΩ: 60°C
1.5 to 1.8 kΩ: 80°C
8
U-phase coil temperature GND
3
W-phase coil temperature
Measure the resistance value between the terminal No. 3 - No. 9 with the connector disconnected.
9
W-phase coil temperature GND
4 - 6
-
-
-
10 - 13
-
-
-