Code No. P1A3D:
AD reference voltage abnormality (MCU)
ELECTRIC MOTOR UNIT CONTROL SYSTEM CIRCUIT
DIAGNOSIS CODE SET CONDITIONS
If a reference voltage abnormality of the integrated AD conversion module for current
and voltage measurement continues for the specific period, the MCU will set the diagnosis code
No. P1A3D.
PROBABLE CAUSES
Unstable voltage of the auxiliary battery
Malfunction of the MCU
DIAGNOSIS PROCEDURE
STEP 1. Use M.U.T.-III to confirm a diagnosis code of
other systems.
Check if the diagnosis code is set to the EV-ECU.
Q.
Is the diagnosis code set?
Carry out troubleshooting for the EV-ECU. (Refer to .) Then
go to Step 2.
Go to Step 2.
STEP 2. Measure the voltage at E-06 MCU connector.
(1)Disconnect the E-06 MCU connector, and measure the voltage at the wiring harness side.
(2)Turn the electric motor switch to the "ON" position.
(3)Measure the voltage between the E-06 MCU connector No.5 - the body earth. OK: Battery voltage