Code No. P1A3F: CPU temperature sensor error (MCU)




DIAGNOSIS CODE SET CONDITIONS


If the ambient temperature of CPU is abnormal, the MCU will set the diagnosis code No. P1A3F.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Diagnosis code recheck


Check again if the diagnosis code is set to the MCU.
(1)Erase the stored diagnosis code.
(2)Set the electric motor switch from the LOCK (OFF) position to the ON position.
(3)Check if the diagnosis code is set.

Q. Is any diagnosis code set?

Replace the MCU. (Refer to .) Then go to Step 2.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction .)

STEP 2. Diagnosis code recheck


Check again if the diagnosis code is set to the MCU.
(1)Erase the stored diagnosis code.
(2)Set the electric motor switch from the LOCK (OFF) position to the ON position.
(3)Check if the diagnosis code is set.

Q. Is the diagnosis code set?

Return to Step 1.
The diagnosis is complete.