1.After the electric motor switch is "LOCK" (OFF) position, connect the M.U.T.-III to the
diagnosis connector. 2.Turn the electric motor switch to the READY position. 3.Select "BMU" from System Select Screen of the M.U.T.-III. 4.Select "Special Function" from BMU Screen. 5.Select " Cell voltage smoothing" from Special Function Screen. 6.Press the OK button to smooth the cell voltage. 7.Check the "Execution status" displayed on the M.U.T.-III and check that the "Acitve"
changes to the "Not Acitve".
| note |
It may take a maximum of 2 hours until smoothing the battery cell voltage is completed.
|
|