MSB is released for this page as follows:
Release DateSubjectMSB No.
2010-11-20MAIN AND AUXILIARY BATTERIES SERVICE PROCEDURESMSB-10E00-018
2011-06-20MAIN AND AUXILIARY BATTERIES SERVICE PROCEDURESMSB-11E00-004

CHECK ON COIL RESITANCE OF CONTACOTOR


danger Be sure to pull service plugs to shut down high voltage for servicing the high voltage system components (Refer to ).
danger When pulling service plugs, wear the specified protective equipment (Refer to ).

CHECK ON COIL RESITANCE OF CHARGING CONTACOTOR



1.Disconnect the main battery connector "A".

2.Measure the resistance between terminal No. 7 and No. 5 of the main battery connector "A".
Standard value: 33 - 39 Ω (at 23°C)
3.If the resistance deviates from the standard value, replace main battery.

CHECK ON COIL RESITANCE OF MAIN CONTACOTOR (+)



1.Disconnect the main battery connector "A".

2.Measure the resistance between terminal No. 3 and No. 5 of the main battery connector "A".
Standard value: 19 - 22 Ω (at 23°C)
3.If the resistance deviates from the standard value, replace main battery.

CHECK ON COIL RESITANCE OF MAIN CONTACOTOR (-)



1.Disconnect the main battery connector "A".

2.Measure the resistance between terminal No. 6 and No. 5 of the main battery connector "A".
Standard value: 19 - 22 Ω (at 23°C)
3.If the resistance deviates from the standard value, replace main battery.