1.Remove the front floor covers A and B. (Refer to GROUP 51 - Under Cover .)
|
|
|
2.Remove the work hole lid for the main battery. (Refer to .)
|


|
3.Remove each mounting bolt and remove each high-voltage fuse. 4.check the resistance between the high-voltage fuses, and if there is no continuity (open circuit), replace the high-voltage fuses.
|

|
5.
| caution |
When tightening the mounting bolts, secure the high-voltage fuse terminal portion, because there is a risk of damage to the high-voltage fuse when an excessive force applies to the high-voltage fuse main body.
|
Tighten each mounting bolt to the specified torque. Tighten each mounting bolt for the high-voltage fuse No. 2 and 3 to the specified torque using the torque wrench (special tool: MB992294). Tightening torque:
High-voltage fuse No. 1: 9.0 ± 3.0 N·m High-voltage fuse No. 2 and 3: 7.0 ± 3.0 N·m
6.Install the work hole lid for the main battery. (Refer to .) 7.Install the front floor covers A and B. (Refer to GROUP 51 - Under Cover .)
|