Check Condition
- The electric motor switch is "ON" position or while the main battery is charged.
|
|
|
Judgement Criterion
- The power supply voltage of the main battery current sensor is more than 5.3 V.
|
|
|
- The power supply voltage of the main battery current sensor is less than
4.7 V.
|
|
|
- Turn off the balancer drive.
|
|
|
- The main battery current sensor is failed.
- Open circuits of main battery current sensor circuit, short circuits to earth or
damage; poor contact of connector.
- The BMU is failed.
|
|
|
Q.
Is the check result normal?
|
|
|
- Disconnect connector, and measure at harness side.
- Electric motor switch: ON
- Voltage between terminal No. 2 and earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Q.
Is the check result normal?
|
|
|
- Check power supply line for open circuit, short circuit to earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
|
|
- Check main battery current sensor itself. (Refer to
).
|
|
|
Q.
Is the check result normal?
|
|
|
Replace the main battery.
|
|
|
|
|
|
- Check power supply line for damage.
|
|
|
Q.
Is the check result normal?
|