Check Conditions
- 3.5 seconds elapse after the electric motor switch is turned ON, or 2 seconds elapse
after the main battery starts to be charged.
- The pre-check signal is OFF.
- Not during the quick charge.
|
|
|
Judgement Criterion
- For more than 5 seconds, ground fault is detected.
|
|
|
- Ground fault of high voltage system component
- The quick charging contactor (+) or the quick charging contactor (-)
is stuck in ON.
- The BMU is failed.
|
|
|
- Electric motor switch: 20 seconds elapse after ON
- Select lever position: P range
|
|
|
Q.
Is the diagnosis code set?
|
|
|
If the diagnosis code is output during the electric motor switch ON, the ground
fault could occur inside the main battery. Replace the main battery.
|
|
|
|
|
|
- During the quick charging
|
|
|
Q.
Is the diagnosis code set?
|
|
|
If the diagnosis code is output during the quick charging, the quick charging
contactor (+) or the quick charging contactor (-) could be stuck in the ON position.
Replace the main battery.
|
|
|
|
|
|
- Electric motor switch: READY
- Select lever position: P range
- A/C switch: OFF
|
|
|
Q.
Is the diagnosis code set?
|
|
|
- Electric motor switch: READY
- Select lever position: D range
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Q.
Is the check result normal?
|
|
|
- Disconnect connector, and measure at harness side.
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Q.
Is the check result normal?
|
|
|
- Disconnect connector, and measure at harness side.
- Disconnect G-16 motor (electric motor unit: U terminal) connector.
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Replace harness between G-07 inverter (U terminal) connector and G-16 motor (electric
motor unit: U terminal) connector.
|
|
|
|
|
|
Q.
Is the check result normal?
|
|
|
- Disconnect connector, and measure at harness side.
- Disconnect G-15 motor (electric motor unit: V terminal) connector
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Replace harness between G-08 inverter (W terminal) connector and G-15 motor (electric
motor unit: V terminal) connector.
|
|
|
|
|
|
Q.
Is the check result normal?
|
|
|
- Disconnect connector, and measure at harness side.
- Disconnect G-14 motor (electric motor unit: W terminal) connector
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Replace the motor (electric motor unit).
|
|
|
|
|
|
Replace harness between G-09 inverter (W terminal) connector and G-14 motor (electric
motor unit: W terminal) connector.
|
|
|
|
|
|
- Electric motor switch: READY
- A/C set temperature: minimum temperature
- A/C switch: ON
- MAX switch: ON
|
|
|
Q.
Is the diagnosis code set?
|
|
|
- Electric motor switch: READY
- A/C set temperature: minimum temperature
- A/C switch: ON
- MAX switch: ON
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Replace the A/C compressor.
|
|
|
|
|
|
- Electric motor switch: READY
- A/C set temperature: maximum temperature
- MAX switch: ON
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Replace the electric hot water heater.
|
|
|
|
|
|
- Electric motor switch: "LOCK" (OFF)
- During the regular charging
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Replace the on board charger/DC-DC converter.
|
|
|
|
|
|
Intermitent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
|
|
- Measure the insulation resistance with the connector connected.
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Check on main battery ground fault detector circuit (Refer to Code No. P1A46:
Detection circuit of main battery ground fault detector abnormal )
|
|
|
|
|
|
- Measure the insulation resistance with the connector connected.
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
When the G-20 A/C compressor connector is disconnected, does the insulation resistance
change by the value more than 10 MΩ?
|
|
|
The A/C compressor could have ground fault. Replace the A/C compressor.
|
|
|
|
|
|
- Measure the insulation resistance with the connector connected.
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
When the G-21 heater connector is disconnected, does the insulation resistance change
by the value more than 10 MΩ?
|
|
|
The heater could have ground fault. Replace the heater.
|
|
|
|
|
|
- Measure the insulation resistance with the connector connected.
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
When the G-05 inverter (- terminal) connector and the G-06 inverter (+ terminal)
connector are disconnected, does the insulation resistance change by the value more than 10
MΩ?
|
|
|
Q.
Is the check result normal?
|
|
|
- Disconnect connector, and measure at harness side.
- Disconnect G-18 main battery connector
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Replace harness between G-05 inverter (- terminal) connector and G-18
main battery connector.
|
|
|
|
|
|
- Disconnect connector, and measure at harness side.
- Disconnect G-19 main battery connector
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
Is the check result normal?
|
|
|
The main battery could have ground fault. Replace the main battery.
|
|
|
|
|
|
Replace harness between G-06 inverter (+ terminal) connector and G-19
main battery connector.
|
|
|
|
|
|
- Measure the insulation resistance with the connector connected.
- Use the special tool electric insulation tester (MB992355) to set the range to 500
V.
- Insulation resistance between terminal No. 1 and body earth.
|
|
|
Q.
When the G-13 on board charger/DC-DC converter connector is disconnected, does the
insulation resistance changes by the value more than 10 MΩ?
|
|
|
The on board charger/DC-DC converter could have ground fault. Replace the on board
charger/DC-DC converter.
|
|
|
|
|
|
- Recheck if the diagnosis code is set again after replacing the inverter.
|
|
|
Q.
Is the diagnosis code set?
|