Code No. P1A47: Power Supply Of Main Battery Cooling Fan Relay Abnormal (Short Circuits To Power Supply System, Open Circuits)










TROUBLE JUDGMENT


Check Condition
  • Every time after the BMU is activated.
Judgement Criterion
  • While the main battery cooling fan relay output is turned OFF, the output status signal of the main battery cooling fan relay is turned ON (during the drive).

FAIL-SAFE AND BACKUP FUNCTION



  • Not available

PROBABLE CAUSES



  • Open circuits of main battery cooling fan relay, short circuits to power supply system or damage; poor contact of connector
  • The BMU is failed.

DIAGNOSIS PROCEDURE


STEP 1. Connector check: A-115X main battery cooling fan relay connector


Q. Is the check result normal?

Go to Step 2 .
Repair.

STEP 2. Check the main battery cooling fan relay itself.



  • Check the main battery cooling fan relay itself (Refer to ).

Q. Is the check result normal?

Go to Step 3 .
Replace the main battery cooling fan relay.

STEP 3. Perform resistance measurement at A-115X main battery cooling fan relay connector



  • Remove the relay, and measure at relay box side.
  • Resistance between terminal No. 1 and earth.
OK: Continuity (2 Ω or less)

Q. Is the check result normal?

Go to Step 4 .

    Check intermediate connector B-122, and repair if necessary. If intermediate connector is normal, Check and repair harness between A-115X (terminal No. 1) main battery cooling fan relay connector and body earth.

    • Check earthing line for open circuit and damage.

STEP 4. Connector check: C-107 BMU connector


Q. Is the check result normal?

Go to Step 5 .
Repair.

STEP 5. Check harness between A-115X (terminal No. 2) main battery cooling fan relay connector and C-107 (terminal No. 12) BMU connector.


note Before checking harness, check intermediate connector B-01, and repair if necessary.

  • Check output line for open circuit and damage.

Q. Is the check result normal?

Go to Step 6 .
Repair.

STEP 6. Perform voltage measurement at C-107 BMU connector



  • Measure BMU terminal voltage.
  • Disconnect A-115X main battery cooling fan relay.
  • Electric motor switch: ON
  • Voltage between terminal No. 12 and earth.
OK: 0 - 0.1 V

Q. Is the check result normal?

Go to Step 7 .

    Check intermediate connector B-01, and repair if necessary. If intermediate connector is normal, check and repair harness between A-115X (terminal No. 2) main battery cooling fan relay connector and C-107 (terminal No. 12) BMU connector.

    • Check output line for short circuit to power supply.

STEP 7. M.U.T.-III diagnosis code.


Q. Is the diagnosis code set?

Replace the BMU.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).