TROUBLE JUDGMENT |
Check Conditions
|
Judgement Criterion
|
FAIL-SAFE AND BACKUP FUNCTION |
|
PROBABLE CAUSES |
|
DIAGNOSIS PROCEDURE |
STEP 1. Connector check: C-14 main battery cooling fan connector |
Q.
Is the check result normal?
|
Go to Step 2 . |
|
Repair. |
|
STEP 2. Perform voltage measurement at C-14 main battery cooling fan connector. |
|
| OK: 0 - 0.1 V |
Q.
Is the check result normal?
|
Go to Step 6 . |
|
Go to Step 3 . |
|
STEP 3. Connector check: C-107 BMU connector |
Q.
Is the check result normal?
|
Go to Step 4 . |
|
Repair. |
|
STEP 4. Check harness between C-14 (terminal No. 2) main battery cooling fan connector and C-107 (terminal No. 13) BMU connector |
|
|
Q.
Is the check result normal?
|
Go to Step 5 . |
|
Repair. |
|
STEP 5. M.U.T.-III diagnosis code. |
Q.
Is the diagnosis code set?
|
Replace the BMU. |
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ). |
|
STEP 6. M.U.T.-III diagnosis code. |
Q.
Is the diagnosis code set?
|
Replace the main battery. |
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ). |
|