Check Conditions
- 3 seconds elapse after the electric motor switch is turned ON, or 3 seconds elapse
after the main battery starts to be charged.
- None of the following diagnosis codes occur at the same time.
- P1AA8: Local CAN (for main battery) signal time-out
- U1082: Local CAN (for main battery) bus off
|
|
|
Judgement Criterion
- The signal is received from the appropriate module CMU, which shows that one of
the module temperatures has an invalid value.
|
|
|
- If the CMU detecting abnormalities also detects the battery cell voltage
sensor abnormalities, drive the main battery cooling fan for 10 minutes.
|
|
|
- The module (battery cell, CMU and module temperature sensor)
in the main battery is failed.
- The BMU is failed.
|
|
|
- Check the data list reference table corresponding to the diagnosis code (Refer
to
).
|
|
|
OK: Not 10°C (initial value) (electric motor switch: "LOCK" (OFF) → ON)
|
|
|
Q.
Is the check result normal?
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
|
|
- After replacing the main battery, reconfirm whether the diagnosis
codes are set.
|
|
|
Q.
Is the diagnosis code set?
|