Check Conditions
- 3 seconds elapse after the electric motor switch is turned ON, or 3 seconds elapse
after the main battery starts to be charged.
- Code No. U1082: Local CAN (for main battery) bus off is not set.
|
|
|
Judgement Criterion
- One of the CMU signals cannot be received through the CAN communication.
|
|
|
- Drive the main battery cooling fan for 10 minutes after judging malfunctions.
|
|
|
- The Local CAN (for main battery) bus is failed.
- The BMU is failed.
|
|
|
- Check the local CAN (for main battery) terminating resistance itself (Refer
to
).
|
|
|
Q.
Is the check result normal?
|
|
|
Replace the main battery.
|
|
|
|
|
|
Q.
Is the check result normal?
|
|
|
- Check signal line for open circuit, short circuit to earth, short circuit
to power supply system and damage.
|
|
|
Q.
Is the check result normal?
|
|
|
- Check signal line for open circuit, short circuit to earth, short circuit
to power supply system and damage.
|
|
|
Q.
Is the check result normal?
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
|
|
- After replacing the main battery, reconfirm whether the diagnosis codes are
set.
|
|
|
Q.
Is the diagnosis code set?
|