Check Conditions
- 3 seconds elapse after the electric motor switch is turned ON, or 3 seconds elapse
after the main battery starts to be charged.
- The following diagnosis code is not set.
- U1082: Local CAN (for main battery) bus off
|
|
|
Judgement Criterion
- For more than 3 seconds, the signal cannot be received from one of CMUs through
the CAN communication.
|
|
|
- The module (CMU) in the main battery is failed.
- The harnesses and the connectors of the local CAN (for main battery) bus.
- Short circuits to earth of CMU power supply circuits; poor contact of connector.
- The BMU is failed.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair it. Then go to Step 13 .
|
|
|
|
|
|
- Disconnect connector, and measure at harness side.
- Electric motor switch: ON
- Voltage between terminal No. 4 and earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Q.
Is the check result normal?
|
|
|

Check intermediate connectors B-27, C-102
and C-112, and repair if necessary. If intermediate connectors are normal, check and repair
harness between A-08X (terminal No. 1) EV control relay connector and C-22 (terminal No. 4)
main battery connector.
- Check power supply line for open/short circuit.
|
|
|
|
|
|
Repair it. Then go to Step 13 .
|
|
|
|
|
|
Q.
Is the check result normal?
|
|
|
Repair or replace the connector, go to Step 13 .
|
|
|
|
|
|
- Check power supply line for damage.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the damaged harness wire, go to Step 13 .
|
|
|
|
|
|
Q.
Is the check result normal?
|
|
|
Repair it. Then go to Step 13 .
|
|
|
|
|
|
- Check the local CAN (for main battery) terminating resistance itself (Refer
to
).
|
|
|
Q.
Is the check result normal?
|
|
|
Replace the main battery. Then go to Step 13 .
|
|
|
|
|
|
Q.
Is the check result normal?
|
|
|
Repair it. Then go to Step 13 .
|
|
|
|
|
|
- Check signal line for open circuit, short circuit to earth, short circuit
to power supply system and damage.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair it. Then go to Step 13 .
|
|
|
|
|
|
- Check signal line for open circuit, short circuit to
earth, short circuit to power supply system and damage.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair it. Then go to Step 13 .
|
|
|
|
|
|
Reconfirm whether the diagnosis codes are set from BMU.
|
|
|
- Erase the diagnosis codes being set.
- Electric motor switch: "LOCK" (OFF) → ON
- Confirm whether the diagnosis codes are set.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
|
|
After replacing the main battery, reconfirm whether the diagnosis codes are set from BMU.
|
|
|
- Erase the diagnosis codes being set.
- Electric motor switch: "LOCK" (OFF) → ON
- Confirm whether the diagnosis codes are set.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Replace the BMU. Then go to Step 13 .
|
|
|
|
|
|
Reconfirm whether the diagnosis codes are set from BMU.
|
|
|
- Erase the diagnosis codes being set.
- Electric motor switch: "LOCK" (OFF) → ON
- Confirm whether the diagnosis codes are set.
|
|
|
Q.
Is the diagnosis code set?
|