MSB is released for this page as follows:
Release DateSubjectMSB No.
2010-11-20MAIN AND AUXILIARY BATTERIES SERVICE PROCEDURESMSB-10E00-018
2011-06-20MAIN AND AUXILIARY BATTERIES SERVICE PROCEDURESMSB-11E00-004
2011-02-20GR54D ELECTRIC MOTOR UNIT AND MAIN BATTERYMSB-11E54-506
2011-06-20GR54D ELECTRIC MOTOR UNIT AND MAIN BATTERYMSB-11E54-510

SERVICE SPECIFICATIONS


Items
Specifications
Charging contactor coil resistance Ω (at 23°C)
33 - 39
Main contactor (+) coil resistance Ω (at 23°C)
19 - 22
Main contactor (-) coil resistance Ω (at 23°C)
19 - 22
Local CAN (for main battery) terminating resistance Ω (at 20°C)
80 - 96
Main battery current sensor resistance kΩ (at 25°C)
main battery connector (13 pin) terminal No. 12 - terminal No. 13
1 - 5
main battery connector (13 pin) terminal No. 5 - terminal No. 13
1 - 5
main battery connector (13 pin) terminal No. 4 - terminal No. 13
1 - 5