CHECK ON MAIN BATTERY CURRENT SENSOR



1.Disconnect the main battery connector "A".

2.Measure the resistance between the terminals of the main battery connector "A".

Standard value:
Measured terminal
Resistance value
2 - 8
1 - 5 kΩ (at 25°C)
3 - 8
1 - 5 kΩ (at 25°C)
7 - 8
1 - 5 kΩ (at 25°C)
3.If different from the standard value, the main battery must be replaced.