MSB is released for this page as follows:
Release DateSubjectMSB No.
2010-11-20MAIN AND AUXILIARY BATTERIES SERVICE PROCEDURESMSB-10E00-018
2011-06-20MAIN AND AUXILIARY BATTERIES SERVICE PROCEDURESMSB-11E00-004
2013-10-10Power switch operation at the time of the M.U.T.-III communicationMSB-13EXML00-003

CHECK ON MAIN BATTERY CAPACITY


note Measuring the main battery capacity enables the check on the main battery capacity (Refer to ).
note This procedure is to check the main battery capacity on the vehicle. This is not to judge whether the main battery is good or not. The energy level of the main battery gradually decreases with the elapse of time and depending on the operating conditions.


1.Connect the diagnosis connector to the M.U.T.-III with electric motor switch in the "LOCK" (OFF) position.
2.From the System Selection Screen of the M.U.T.-III, select the "BMU".
3.Select the "Data List" from the BMU Screen.
4.Check the BMU data list, Item No. 368: Cell current capacity (measured).
5.Turn the electric motor switch to the "LOCK" (OFF) position, and disconnect the M.U.T.-III.