DIAGNOSIS FUNCTION



WHEN DETECTING ON BOARD CHARGER ABNORMALITY


When the on board charger detects the abnormality, the diagnosis code should be output. The EV-ECU monitors to check whether the on board charger has abnormalities or not.

METHOD OF READING AND ERASING DIAGNOSIS CODES


Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - Diagnosis Function .

FAIL-SAFE AND BACKUP FUNCTION


The control is carried out, which keeps the safety driving by the preset control logic when the diagnostic trouble code is set. The diagnostic trouble code having the fail-safe function is as follows.

List of fail-safe and backup function items
Code No.
Diagnosis item
Fail-safe control
01
Output voltage abnormal

  • The charge is stopped

02
Load connection abnormal (main battery not connected)

  • The charge is stopped

03
Output current abnormal

  • The charge is stopped

04
Control power supply voltage abnormal

  • The charge is stopped

06
AC input voltage abnormal

  • The charge is stopped

11
Voltage command abnormal

  • The charge is stopped

12
Current command abnormal

  • The charge is stopped

13
EV-ECU lost

  • The charge is stopped

15
Power factor correction (PFC) circuit temperature abnormal

  • The charge is stopped

16
Temperature in increasing voltage area abnormal

  • The charge is stopped

17
Inside ambient temperature abnormal (boost circuit rectifier temperature abnormal)

  • The charge is stopped

27
AC input current abnormal

  • The charge is stopped

28
EEPROM abnormal

  • The charge continues at the initial value.

29
Pilot signal abnormal

  • The charge is stopped

30
Electric motor circuit abnormal

  • The charge is stopped

31
Temperature in increasing voltage area abnormal 2

  • The charge is stopped

33
ROM/RAM abnormal

  • The charge is stopped

35
AD conversion module abnormal

  • The charge is stopped

39
Power factor correction (PFC) circuit output voltage abnormal

  • The charge is stopped

41
Input current sensor 0 point abnormal

  • The charge is stopped

42
Output current sensor 0 point abnormal

  • The charge is stopped

43
Inverter overcurrent abnormal

  • The charge is stopped

44
Rectification overvoltage abnormal

  • The charge is stopped

45
Rectification overcurrent abnormal

  • The charge is stopped