MSB is released for this page as follows:
Release DateSubjectMSB No.
2018-04-16Addition of the maintenance procedure for ON BOARD CHARGER/DC-DC CONVERTER due to change the specification of service partsMSB-18EXML54-002

INSPECTION CHART FOR DIAGNOSIS CODE


Code No.
Diagnosis item
Reference page
01
Output voltage abnormal

02
Load connection abnormal (main battery not connected)

03
Output current abnormal

04
Control power supply voltage abnormal

06
AC input voltage abnormal

11
Voltage command abnormal

12
Current command abnormal

13
EV-ECU lost

15
Power factor correction (PFC) circuit temperature abnormal

16
Temperature in increasing voltage area abnormal

17
Inside ambient temperature abnormal (boost circuit rectifier temperature abnormal)

26
Charging current limited (temperature increase)

27
AC input current abnormal

28*1
EEPROM abnormal

29
Pilot signal abnormal

30
Electric motor circuit abnormal

31
Temperature in increasing voltage area abnormal 2

32
Charging current limited (input voltage decrease)

33*1
ROM/RAM abnormal

35*1
AD conversion module abnormal

39
Power factor correction (PFC) circuit output voltage abnormal

41
Input current sensor 0 point abnormal

42
Output current sensor 0 point abnormal

43*1
Inverter overcurrent abnormal

44*1
Rectification overvoltage abnormal

45*1
Rectification overcurrent abnormal

note When once detecting a malfunction, the on board charger should store it. When detecting again the same malfunction as the previous one during the operation after the next activation, the on board charger should judge that the malfunction occurs. When detecting the malfunction at the just first time, the on board charger judges that the malfunction occurs, which is marked with *1 in the diagnosis code chart.