Inspection Procedure 12: Domestic circuit breaker interrupts the power supply.




PROBABLE CAUSES



  • Simultaneous use with other household electric appliances in the home
  • An adapter or the like is connected to the charging cable plug
  • charging cable
  • Malfunction of the on board charger
  • Malfunction of the domestic power supply facility

DIAGNOSIS PROCEDURE


STEP 1. AC 200 V charging cable check


Check if the fault indication of the electric leakage breaker incorporated in the charging cable is flashing. Then, check the charging cable. (Refer to .)

Q. Is the check result normal?

Go to Step 2.
Replace the charging cable. Then go to Step 2.

STEP 2. Check the current capacity of the domestic power supply facility.


Check if the current capacity is lower than the current limit of the electric leakage breaker incorporated in the charging cable.

Q. Is the check result normal?

Go to Step 3.

    Repair the domestic power supply facility.

STEP 3. Check the trouble symptom.


Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction .)
Check the domestic power supply facility for electric leakage.