Check Conditions
- During regular charging
- The on board charger control power supply voltage is more than 8 V.
|
|
|
Judgement Criterion
- For more than 10 seconds, the effective value of AC input voltage is more than 40
V and less than 80 V.
|
|
|
- The effective value of AC input voltage is more than 265 V.
|
|
|
- The effective value of AC input voltage is more than 300 V for a moment.
|
|
|
- The AC power supply (at the supply side) is abnormal.
- The charging cable is failed.
- The on board charger is failed.
|
|
|
- Charge the main battery (Refer to GROUP 00 - Precautions
before Service - Precautions at charging
). After charging
the main battery, check the diagnosis code.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Check the AC power supply usage conditions used by the users.
|
|
|
|
|
|
- Check charging cable (Refer to
).
|
|
|
Q.
Is the check result normal?
|
|
|
Replace the charging cable.
|
|
|
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Replace the on board charger/DC-DC converter.
|
|
|
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|