Code No. 06: AC Input Voltage Abnormal




TROUBLE JUDGMENT


Check Conditions
  • During regular charging
  • The on board charger control power supply voltage is more than 8 V.
Judgement Criterion
  • For more than 10 seconds, the effective value of AC input voltage is more than 40 V and less than 80 V.
or

  • The effective value of AC input voltage is more than 265 V.
or

  • The effective value of AC input voltage is more than 300 V for a moment.

FAIL-SAFE AND BACKUP FUNCTION



  • The charge is stopped.

PROBABLE CAUSES



  • The AC power supply (at the supply side) is abnormal.
  • The charging cable is failed.
  • The on board charger is failed.

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III diagnosis code



  • Charge the main battery (Refer to GROUP 00 - Precautions before Service - Precautions at charging ). After charging the main battery, check the diagnosis code.

Q. Is the diagnosis code set?

Go to Step 2 .
Check the AC power supply usage conditions used by the users.

STEP 2. Check charging cable itself



  • Check charging cable (Refer to ).

Q. Is the check result normal?

Go to Step 3 .
Replace the charging cable.

STEP 3. M.U.T.-III diagnosis code


Q. Is the diagnosis code set?

Replace the on board charger/DC-DC converter.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).