Code No. 11: Voltage Command Abnormal




TROUBLE JUDGMENT


Check Conditions
  • The on board charger control power supply voltage is more than 8 V.
  • While the on board charger is allowed to be charged from the EV-ECU.
Judgement Criterion
  • The charging voltage command from the EV-ECU exceeds 370 V (upper limit).
or

  • The charging voltage command from the EV-ECU is less than 0 V.

FAIL-SAFE AND BACKUP FUNCTION



  • The charge is stopped.

PROBABLE CAUSES



  • The EV-ECU is failed.
  • The on board charger is failed.

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III other system diagnosis code.


Q. Is diagnosis code of EV-ECU system set?

Check EV-ECU system (Refer to ).
Go to Step 2 .

STEP 2. M.U.T.-III diagnosis code


Q. Is the diagnosis code set?

Replace the on board charger/DC-DC converter.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).





Yandex.Metrika
MMC-Manuals.ru