Code No. 15: Power Factor Correction (PFC) Circuit Temperature Abnormal




TROUBLE JUDGMENT


Check Conditions
  • When the charging cable is connected.
  • The on board charger control power supply voltage is more than 8 V.
or

  • While the electric motor switch is turned ON with the M.U.T.-III connected.
  • The on board charger control power supply voltage is more than 8 V.
Judgement Criterion
  • For more than 2 seconds, the power factor improvement circuit (PFC) temperature sensor is more than 115° C.

FAIL-SAFE AND BACKUP FUNCTION



  • The charge is stopped.

PROBABLE CAUSES



  • There is not enough coolant.
  • The water pump is failed.
  • The radiator fan is failed.
  • The temperature sensor installed in the on board charger is failed.

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III other system diagnosis code.


Q. Is diagnosis code of EV-ECU system set?

Check EV-ECU system (Refer to ).
Go to Step 2 .

STEP 2. Check the coolant.


note If the coolant largely decreases, check whether the coolant leakage exists or not. Repair it if necessary.

  • Check on coolant (Refer to GROUP 14 - On-vehicle Service - Coolant Check ).

Q. Is the check result normal?

Go to Step 3 .
Replace or supply the coolant.

STEP 3. M.U.T.-III actuator test



  • Refer to the Actruator Test Reference Table of the EV-ECU, .

    1. Item 3: Water pump drive
    2. Item 4: Radiator fan 1 drive
    3. Item 5: Radiator fan 2 drive
    4. Item 9: Water pump drive 2

Q. Is the check result normal?

Go to Step 4 .
Go to the check procedures for the diagnosis code for the actuator which has an abnormal drive (Refer to ).

STEP 4. M.U.T.-III diagnosis code


Q. Is the diagnosis code set?

Replace the on board charger/DC-DC converter.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).