Code No. 32: Charging Current Limited (input voltage decrease)



note This diagnosis code shows the history of protective control.

TROUBLE JUDGMENT


Check Condition
  • The on board charger relay is turned ON.
Judgement Criterion
  • If the output is limited for more than 10 seconds due to the AC input voltage decrease [the AC input voltage is less than 81 V].

FAIL-SAFE AND BACKUP FUNCTION



  • Not available

PROBABLE CAUSES



  • The AC power supply (at the supply side) is abnormal.
  • The charging cable is failed.
  • The on board charger is failed.

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III diagnosis code



  • Charge the main battery (Refer to GROUP 00 - Precautions before service - Precautions at charging ). After charging the main battery, check the diagnosis code.

Q. Is the diagnosis code set?

Go to Step 2 .
Check the AC power supply usage conditions used by the users.

STEP 2. Check charging cable itself



  • Check charging cable itself (Refer to ).

Q. Is the check result normal?

Check end.
Replace the charging cable.