Code No. 41: Input Current Sensor 0 Point Abnormal




TROUBLE JUDGMENT


Check Conditions
  • The on board charger control power supply voltage is more than 8 V.
  • While the on board charger is allowed to be charged from the EV-ECU.
Judgement Criterion
  • Input current sensor is less than -1.5 A or more than 1.5 A.

FAIL-SAFE AND BACKUP FUNCTION



  • The charge is stopped.

PROBABLE CAUSE



  • The on board charger is failed.

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III diagnosis code


Q. Is the diagnosis code set?

Replace the on board charger/DC-DC converter.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).