Code No. B1107 Electric compressor input voltage (high)






DIAGNOSIS CODE SET CONDITIONS


This code is set when the overvoltage abnormality (high voltage of DC 425 V or more is detected for 3 seconds) judged by the A/C compressor inverter is detected.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Check the high-voltage connector and wiring harness.


danger Carry out the check on the high-voltage circuit while reading carefully the precautions on handling a high-voltage vehicle. Refer to .
danger Wear the specified protection equipment during the check.
1.Shut down the high voltage. (Refer to GROUP 00 - Precautions before Service - Precautions on handling high-voltage vehicle .)
2.G-20 Check the A/C compressor connector.
3.Visually check the following high-voltage wiring harnesses for damage.

Q. Is the check result normal?

Go to Step 2.
NO <Malfunction of connector and wiring harness on A/C compressor side> : Replace the A/C compressor.
NO <Malfunction of wiring harness on main battery side> : Replace the main battery.

STEP 2. Check whether the diagnosis code is reset.


Q. Is the diagnosis code set?

Go to Step 3.
Intermittent malfunction. Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points, - How to Cope with Intermittent Malfunctions .)

STEP 3. After replacing the A/C compressor, check again if the diagnosis code is set.


Q. Is the diagnosis code set?

Replace the main battery.
This diagnosis is complete.