STEP 17. Check the wiring harness between A-114X heater water pump
relay connector terminal No. 1 and C-101 A/C control unit connector terminal No. 7.
Check the power supply line for open circuit.
note
Before checking the wiring harness, check the intermediate connector B-27 and repair it
if necessary.
Q.
Is the check result normal?
Go to Step 18.
Repair the wiring harness.
STEP 18. Check the wiring harness between A-114X heater water pump
relay connector terminal No. 3 and A-109 heater water pump assembly connector terminal No. 1.
Check the power supply line for open circuit.
Q.
Is the check result normal?
Go to Step 19.
Repair the wiring harness.
STEP 19. Check the wiring harness between A-109 heater water pump
assembly connector terminal No. 1 and C-113 A/C control unit connector terminal No. 29.
Check the input line for open circuit.
note
Before checking the wiring harness, check the intermediate connector B-27 and repair it
if necessary.
Q.
Is the check result normal?
Go to Step 20.
Repair the wiring harness.
STEP 20. Connector check: A-113 heater connector
Q.
Is the check result normal?
Go to Step 21.
Repair the damaged connector.
STEP 21. Check the wiring harness between A-113 heater connector terminal
connector terminal No. 6, 7, 8, 1, 2, 3, 4, 5 and C-101 A/C control unit connector terminal
No. 19, 17, 18, C-113 compressor & heater controller connector terminal No. 25, 33,
34, 35, 36.
Check the input line for open circuit.
note
Before checking the wiring harness, check the intermediate connector B-01 and repair it
if necessary.
Q.
Is the check result normal?
Go to Step 22.
Repair the wiring harness.
STEP 22. Check whether the diagnosis code is reset.
Q.
Is the diagnosis code set?
Go to Step 23.
Intermittent malfunction. Refer to GROUP 00 - How to
Use Troubleshooting/Inspection Service Points, - How to Cope with Intermittent Malfunctions .)
STEP 23. After replacing the compressor & heater controller,
check again if the diagnosis code is set.