DIAGNOSIS PROCEDURE |
STEP 1. Connector check: B-10-3 outside/inside air selection damper motor and potentiometer connector, C-113, C-101 compressor & heater controller connector |
Q.
Is the check result normal?
|
Go to Step 2. |
|
Repair the damaged connector. |
|
STEP 2. Check the wiring harnesses between B-22-3 outside/inside air selection damper motor and potentiometer connector terminal No. 3 and C-115 compressor & heater controller connector terminal No. 24, and B-22-3 outside/inside and potentiometer connector terminal No. 5, 7 and C-101 A/C control unit connector terminal No. 20, 19. |
|
|
Q.
Is the check result normal?
|
Go to Step 3. |
|
Repair the wiring harness. |
|
STEP 3. Check the outside/inside and potentiometer. |
Refer to . |
Q.
Is the check result normal?
|
Go to Step 4. |
|
Replace the air recirculation/fresh air selection damper
motor and potentiometer. |
|
STEP 4. Check whether the diagnosis code is reset. |
Q.
Is the diagnosis code set?
|
Replace the compressor & heater controller. |
|
Intermittent malfunction. Refer to GROUP 00 - How to