Use the M.U.T.-III to diagnose the CAN bus lines.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the CAN bus lines. (Refer to GROUP 54C - Troubleshooting . ) After repairing the CAN bus lines, go to STEP 6.
|
|
|
|
|
|
Check if a combination meter-related diagnosis code is set.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Carry out the troubleshooting of the combination meter. Refer to .
|
|
|
|
|
|
Check if a diagnosis code, which relates to the CAN communication-linked systems below, is set.
|
|
|
- ETACS-ECU
U1108:
Combination meter timeout
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Recheck if the diagnosis code is set.
|
|
|
- Erase the stored diagnosis code.
- Electric motor switch position: LOCK (OFF) → ON
- Check the diagnosis code.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Replace the combination meter, and then go to STEP 6.
|
|
|
|
|
|
A poor connection, open circuit or other intermittent malfunction is present in the CAN bus line between the combination meter and compressor & heater controller. (Refer to GROUP 00 - How to Cope with Intermittent Malfunction .)
|
|
|
|
|
|
Recheck if the diagnosis code is set.
|
|
|
- Erase the stored diagnosis code.
- Electric motor switch position: LOCK (OFF) → ON
- Check the diagnosis code.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
After replacing the compressor & heater controller, go to step 6.
|
|
|
|
|
|
A poor connection, open circuit or other intermittent malfunction is present in the CAN bus line between the combination meter and compressor & heater controller. (Refer to GROUP 00 - How to Cope with Intermittent Malfunction .)
|
|
|
|
|
|
Recheck if the diagnosis code is set.
|
|
|
- Erase the stored diagnosis code.
- Electric motor switch position: LOCK (OFF) → ON
- Check the diagnosis code.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
The procedure is complete.
|
|
|
|