1.Use the following special tools.
- Radiator cap tester (MB992193)
- Radiator cap tester adapter set (MB992190)
2.
| caution |
Check that a foreign material does not adhere the seal portion of the heater condenser tank cap and apply the water.
|
Install the heater condenser tank cap onto the special tool and check that the opening pressure stays at the standard value range. Standard value: 14 to 44 kPa 3.If the value is not within the standard range, replace the heater condenser tank cap.
|

|
4.Install the heater condenser tank cap securely onto the lock position of the heater condenser tank until a click is heard.
|