CHECK AT ECU TERMINAL <HEATER CONTROLLER (A/C-ECU)>




Terminal No.
Check items
Inspection conditions
Normal conditions
1
Air mix damper motor (HOT)
When shifting to HOT
System voltage
When shifting to COOL
0 to 1 V
2
Air outlet changeover damper motor (FACE)
When moving toward FACE position
System voltage
When moving toward DEF position
1 V or less
3 - 6
-
-
-
7
Communication with the diagnosis connector
-
0 to 12 V
8
Back-up power supply
Always
System voltage
9
-
-
-
10
Electric motor switch power supply
Electric motor switch: ON
System voltage
11
Heater water temperature sensor
Temperature at the sensor 25°C (5 kΩ)
2.1 to 2.7 V
12
Air mix damper motor (COOL)
When shifting to COOL
System voltage
When shifting to HOT
1 V or less
13
Air outlet changeover damper motor (DEF)
When moving toward DEF position
System voltage
When moving toward FACE position
1 V or less
14
-
-
-
15
Communication with the compressor & heater controller
-
-
16
Compressor & heater controller earth
-
1 V or less
17 to 21
-
-
-
22
Earth
Always
0 V
31
Ambient temperature sensor
Temperature at the sensor 25°C (1.7 kΩ)
2.1 to 2.7 V
32
Air mix damper motor (potentiometer input)
Air mix damper motor MAX COOL position
0 to 1.5 V
33
Air outlet changeover damper motor (potentiometer input)
Air outlet changeover damper motor FACE position
1 V or less
34
Sensor power supply
Electric motor switch: ON
5 V
35
Power transistor
Air volume adjustment dial: Maximum
System voltage
36
Power transistor
Air volume adjustment dial: Maximum
0 to 2 V
37
ILL power supply
Lighting switch: ON
System voltage
38
Sensor earth
Always
0 V
39
Fin thermo sensor
Temperature at the sensor 0°C (4.8 kΩ)
2.1 to 2.7 V
40 to 43
-
-
-
44
ILL earth
Always
0 V