MSB is released for this page as follows:
Release DateSubjectMSB No.
2012-03-16INFORMATION ON 2012.5 i-MiEVMSB-12E00-002A

DIAGNOSIS CODE CHART <COMPRESSOR & HEATER CONTROLLER>


Code No.
Diagnostic item
Reference page
Service data display contents when diagnosis code is set
B1081
Control panel comm.error

-
B1083
EEPROM fail

-
B1101
ELC. compressor (Eternity)

-
B1102
ELC. compressor (Current)

-
B1103
ELC. compressor (Power)

-
B1104
ELC. compressor (Heat)

-
B1105
ELC. compressor (Communication)

-
B1106
ELC. compressor input VOLT.(low)

-
B1107
ELC.compressor input VOLT.(high)

-
B1108
Electric water heater fail 1

-
B1109
Electric water heater fail 2

-
B1110
Electric water heater fail 3

-
B1111
ELC.water heater inlet SNS.low

95°C
B1112
ELC.water heater inlet SNS.high

B1113
ELC.water heater outlet SNS.low

B1114
ELC.water heater outlet SNS.high

B1115
Electric water pump malfunction

-
B1116
Electric water pump harness

-
B1117
ELC.compressor (Control)

-
B1118
ELC.compressor (Temp.Sensor)

-
B1121
In/out select damper circuit HI

-
B1122
In/out select damper circuit LO

-
B1123
In/out select damper malfunction

-
U1073
Bus-off

-
U1100
EV-ECU CAN timeout

-
U1102
ASC/TCL/ABS timeout/Not equipped

-
U1108
Meter CAN timeout/Not equipped

-
U1109
ETACS CAN timeout/Not equipped

-
U111C
BMU CAN timeout

-
U1190
No receive fault detect signal

-





Yandex.Metrika