Inspection Procedure 5: Air recirculation/fresh air selection is not possible.




PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. A/C-ECU M.U.T.-III actuator test


Perform the following actuator tests, and check that the device works normally.

  • Item 05: Outside/inside air selection switch

Q. Does the air recirculation/fresh air selection damper motor work normally?

Go to Step 2.
Replace the A/C-ECU.

STEP 2. A/C-ECU M.U.T.-III service data


Check that the following service data MUT-III display contents are normal.

  • Item 45: Air recirculation/fresh air selection switch (input)
  • Item 46: Air recirculation/fresh air selection switch (output)

Q. Is the check result normal?

Go to Step 3.
Replace the A/C-ECU.

STEP 3. After replacing the A/C-ECU, check the compressor & heater controller M.U.T.-III service data.


Check that the following service data MUT-III display contents are normal.

  • Item 16: Outside/inside air selection damper
  • Item 19: Outside/inside air selection switch

Q. Is the check result normal?

This diagnosis is complete.
Replace the compressor & heater controller.