Inspection Procedure
7: A/C control unit power supply system




PROBABLE CAUSES
- Malfunction of compressor & heater controller
- Damaged harness wires and connectors
|
|
STEP 1. Connector check: C-101 A/C control unit connector
|
|
|
Q.
Is the check result normal?
|
|
|
Go to Step 2.
|
|
|
|
|
|
Repair the damaged connector.
|
|
|
|
|
|
STEP 2. Measure the voltage at C-101 A/C control unit connector.
|
|
|
(1)Disconnect the connector, and measure at the wiring harness side.
|
|
|
(2)Voltage between terminal No. 13 and body earth OK: Battery voltage
|
|
|
Q.
Is the check result normal?
|
|
|
Go to Step 4.
|
|
|
|
|
|
Go to Step 3.
|
|
|
|
|
|
STEP 3. Check the wiring harness between C-101 A/C control unit connector
terminal No. 13 and the fusible link (25).
|
|
|
- Check the power supply line for open circuit.
|
|
|
| note |
Before checking the wiring harness, check the junction block connectors B-301, joint connectors
B-05, and B-06, and repair them if necessary.
|
|
|
|
Q.
Is the check result normal?
|
|
|
Intermittent malfunction. Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points, - How to Cope with Intermittent Malfunctions .)
|
|
|
|
|
|
Repair the wiring harness.
|
|
|
|
|
|
STEP 4. Measure the voltage at B-101 A/C control unit connector.
|
|
|
(1)Disconnect the connector, and measure at the wiring harness side.
|
|
|
(2)Voltage between terminal No. 15 and body earth OK: Battery voltage
|
|
|
Q.
Is the check result normal?
|
|
|
Go to Step 6.
|
|
|
|
|
|
Go to Step 5.
|
|
|
|
|
|
STEP 5. Check the wiring harness between C-101 A/C control unit connector
terminal No. 15 and B-309 A/C relay connector terminal No. 3.
|
|
|
- Check the power supply line for open circuit.
|
|
|
| note |
Before checking the wiring harness, check the junction block connectors B-302 and B-301,
and repair them if necessary.
|
|
|
|
Q.
Is the check result normal?
|
|
|
Intermittent malfunction. Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points, - How to Cope with Intermittent Malfunctions .)
|
|
|
|
|
|
Repair the wiring harness.
|
|
|
|
|
|
STEP 6. Measure the resistance at C-101 A/C control unit connector.
|
|
|
(1)Disconnect the connector, and measure at the wiring harness side.
|
|
|
(2)Resistance between terminal No. 14 and body earth OK: Continuity exists (2 Ω or less)
|
|
|
Q.
Is the check result normal?
|
|
|
Replace the compressor & heater controller.
|
|
|
|
|
|
Go to Step 7 <LHD>.
|
|
|
|
|
|
Go to Step 8 <RHD>.
|
|
|
|
|
|
STEP 7. Check the wiring harness between B-315 A/C control unit connector
terminal No. 14 and earth connector terminal No. 1.
|
|
|
- Check the earth wires for open circuit.
|
|
|
Q.
Is the check result normal?
|
|
|
Intermittent malfunction. Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points, - How to Cope with Intermittent Malfunctions .)
|
|
|
|
|
|
Repair the wiring harness.
|
|
|
|
|
|
STEP 8. Check the wiring harness between B-315 A/C control unit connector
terminal No. 14 and the body earth.
|
|
|
- Check the earth wires for open circuit.
|
|
|
Q.
Is the check result normal?
|
|
|
Intermittent malfunction. Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points, - How to Cope with Intermittent Malfunctions .)
|
|
|
|
|
|
Repair the wiring harness.
|
|
|
|
MMC-Manuals.ru