Inspection Procedure 9: A/C control unit cannot communicate with M.U.T.-III.




COMMENTS ON TROUBLE SYMPTOM


If communication with all other systems is not possible, there is a high possibility that there is a malfunction of the diagnosis line. If only A/C control unit cannot communicate, malfunction of the A/C control unit is suspected.

PROBABLE CAUSES



  • Malfunction of compressor & heater controller

DIAGNOSIS PROCEDURE


M.U.T.-III CAN bus diagnosis


Use the M.U.T.-III to diagnose the CAN bus lines.

Q. Is the check result normal?

Refer to Inspection Procedure: Compressor & heater controller power supply system .
Repair the CAN bus lines. (Refer to GROUP 54C - Troubleshooting .)